How To Reset A Furnace High Limit Switch: A Complete HVAC Safety Guide

How To Reset A Furnace High Limit Switch: A Complete HVAC Safety Guide

What causes furnace limit switch to trip 60 photos - Guidebookbali.com

Resetting a furnace high limit switch involves identifying the manual reset button located on the switch body and pressing it firmly until an audible click is heard, which typically occurs after allowing the unit to cool for 20 to 30 minutes. This safety component is designed to interrupt the electrical circuit to the gas valve when internal plenum temperatures exceed factory-calibrated thresholds—usually between 180°F and 220°F—to prevent catastrophic heat exchanger damage or house fires.


--- Advertisement / Sponsored Links ---
Verified by SecureScan: No Viruses Detected
Format: Adobe PDF Downloads: 12,409 Size: 2.4 MB

Safety Protocols and Pre-Maintenance Requirements

Before attempting to interact with any internal furnace components, it is imperative to understand that the high limit switch is a primary safety device. It does not "fail" without a reason; rather, it trips to prevent a more dangerous scenario. Frequent tripping indicates a systemic issue with airflow or combustion. Handling these components requires a basic understanding of electrical safety and HVAC system architecture.



Technical Readiness Checklist



  • Mandatory Tools: A 1/4-inch or 5/16-inch nut driver (depending on your furnace brand), a high-intensity LED flashlight, and a digital multimeter for continuity testing.
  • Safety Gear: Insulated work gloves and safety glasses are recommended to protect against sharp sheet metal edges and electrical discharge.
  • System Knowledge: You must be able to distinguish between a standard high limit switch (located on the plenum) and a flame rollout switch (located near the burner assembly).
  • Time Benchmark: A standard reset takes approximately 15 to 30 minutes, including cooling time. Troubleshooting the root cause may take an additional hour.
  • Cost Estimate: Manually resetting the switch costs nothing. However, if the switch has suffered internal mechanical failure, a replacement part typically ranges from $15 to $60.

Step-by-Step Furnace High Limit Switch Reset Procedure

The following instructions apply to most forced-air gas furnaces, including brands like Carrier, Trane, Goodman, and Lennox. If your furnace is an older model without a manual reset button, the switch may be an "auto-reset" variety that requires significant cooling time or professional replacement.



Step 1: Terminate Power and Gas Supply

Safety is the absolute priority when working with HVAC equipment. Locate the service switch (often looking like a standard light switch) on the side of the furnace or a nearby wall and flip it to the "Off" position. For added safety, locate the furnace breaker in your main electrical panel and switch it off. While you generally do not need to turn off the gas for a simple reset, doing so at the manual shut-off valve on the incoming gas line provides an extra layer of protection while your hands are near the burner assembly.

Warning: Never attempt to reset or bypass a safety switch while the furnace is receiving power. This can lead to electrical shock or accidental ignition of residual gas.



Step 2: Access the Interior Cabinet

Using your nut driver, remove the screws securing the upper and lower access panels of the furnace. Most modern furnaces have two panels: the burner compartment (top) and the blower compartment (bottom). Remove the upper panel first to locate the limit control. Set the screws aside in a magnetic tray or a secure spot, as these specialized self-tapping screws are easily lost in floor grates.



Step 3: Locate the High Limit Switch

Look for a small, rectangular or circular component mounted directly onto the furnace plenum (the metal box just above the heat exchanger). It will typically have two wires connected to it via spade terminals.



  • High Limit Switch: Usually found in the middle of the furnace cabinet, where it can sense the temperature of the air passing over the heat exchanger.
  • Flame Rollout Switch: Located on the side of the burner box. These are distinct from the high limit switch and trip if flames are "rolling out" of the heat exchanger due to a blockage or crack.


Step 4: Execute the Manual Reset

Examine the center of the limit switch for a small, usually red or orange, button. This is the manual reset trigger.



  1. Wait at least 15 minutes for the furnace to cool down. If the switch is still too hot, the internal bimetallic disc will not allow the reset to hold.
  2. Firmly press the button. You should feel a distinct "click."
  3. If the button feels "mushy" or offers no resistance, the switch may already be reset, or the internal mechanism may have failed.

Pro-Tip: If the switch trips again immediately upon the furnace starting a new cycle, do not continue to reset it. Repeated tripping is a symptom of restricted airflow, such as a severely clogged air filter or a failing blower motor.



Step 5: Conduct a Continuity Test (Optional)

If you have a multimeter, you can verify if the switch is functional. Set your multimeter to the Ohms (Ω) or Continuity setting. Disconnect the two wires from the switch (mark them first to ensure correct reconnection). Place one probe on each terminal of the switch. A functional, reset switch should show "zero" ohms or produce a continuous beep. If it shows "OL" (Open Line), the switch is still tripped or is permanently defective and must be replaced.



Step 6: Identify and Resolve the Root Cause

A high limit switch rarely trips without an external catalyst. Before replacing the panels, check the following:



  • Air Filter: A dirty filter is the #1 cause of high limit trips. It restricts airflow, causing the heat exchanger to overheat.
  • Vents and Returns: Ensure no furniture or rugs are blocking the return air grilles or supply registers.
  • Blower Motor: Check for debris in the blower wheel or signs of motor overheating (burnt smell).


Step 7: System Reassembly and Testing

Replace the access panels, ensuring the safety interlock switch (a small button the panel presses in) is fully engaged. Restore power and gas. Set your thermostat to "Heat" and increase the temperature to trigger a call for heat. Monitor the furnace through one full cycle (usually 10–15 minutes) to ensure the burners do not cut out prematurely.


Goodman furnace high limit switch keeps tripping 60 photos - Arptravels.com

Goodman furnace high limit switch keeps tripping 60 photos - Arptravels.com

High Limit Switch Technical Specifications and Comparisons

Understanding the specific operating parameters of your furnace's safety components helps in diagnosing whether you need a simple reset or a mechanical replacement. The table below outlines the differences between common safety switches found in residential HVAC units.



Switch Type Typical Trip Temperature Reset Method Primary Function
Primary High Limit 180°F - 220°F Manual or Auto Monitors plenum air temperature to prevent overheating.
Flame Rollout 210°F - 350°F Manual (Always) Detects flames escaping the combustion chamber.
Auxiliary Limit 160°F - 180°F Manual Located on the blower housing to detect motor/airflow failure.
Draft Hood Limit 180°F - 240°F Manual Found in older atmospheric furnaces to detect venting backdrafts.

Troubleshooting Common Limit Switch Failures

When a reset does not solve the problem, you must dig deeper into the system's mechanical health. Use the following scenarios to diagnose persistent issues.



Scenario 1: The Switch Trips Immediately After Ignition



  • Root Cause: This is typically caused by a total lack of airflow or a massive heat spike. The most common culprit is a failed blower motor or a broken fan belt (on very old units). If the blower does not move air across the heat exchanger within seconds of the burners igniting, the plenum temperature will spike instantly.
  • Actionable Fix: Check the capacitor on the blower motor or the motor itself. If the motor is humming but not spinning, the capacitor likely needs replacement. If there is no sound, check for a blown fuse on the control board.


Scenario 2: The Switch Trips Only After 10 Minutes of Operation



  • Root Cause: This suggests a gradual heat buildup, often referred to as "low delta-T" issues or restricted airflow. A heavily loaded MERV-13 filter or a clogged secondary heat exchanger (common in high-efficiency 90%+ AFUE furnaces) can cause this slow overheat.
  • Actionable Fix: Remove the air filter temporarily to see if the furnace completes a cycle. If it does, replace the filter with one that has a lower MERV rating or a higher flow rate. If the problem persists, inspect the AC evaporator coil (if applicable) for dust buildup that might be "choking" the furnace.


Scenario 3: The Switch Will Not Reset Manually



  • Root Cause: The bimetallic disc inside the switch has "fatigued" or melted due to repeated tripping or extreme heat exposure. Once the internal mechanical link is broken, the button will no longer engage the circuit.
  • Actionable Fix: The switch is a "single-use" safety item in this state. You must record the Part Number and the Temperature L-rating (e.g., L200-40, which means it opens at 200°F and closes at 160°F) and install an exact OEM replacement.


Scenario 4: The Furnace Runs but the Air is Cold



  • Root Cause: The limit switch may be "stuck open." While it hasn't tripped the manual button, the internal contacts have failed. This prevents the gas valve from receiving the 24V signal required to open, though the inducer fan and blower may still run.
  • Actionable Fix: Use a multimeter to check for 24V AC on both sides of the switch. If you have 24V coming in but 0V going out, and the furnace is cool, the switch is defective.

Frequently Asked Questions



Can I temporarily bypass a high limit switch to get heat through the night?

Under no circumstances should you bypass, jump, or tape down a high limit switch. This component is the final line of defense against a cracked heat exchanger or a house fire. If the switch is tripping, it is doing so because the environment is unsafe for combustion. Bypassing it can lead to carbon monoxide poisoning or catastrophic fire.



Where exactly is the high limit switch located in my furnace?

In most upflow furnaces, the high limit switch is located on the front panel of the heat exchanger wrap, usually behind the gas valve or slightly above the burner tubes. It is a small component with two wires. If you follow the wires from the gas valve, one of them will often lead directly to the limit switch circuit.



Why does my furnace keep tripping the limit switch even with a clean filter?

If the filter is clean, the issue is likely "static pressure." This occurs when the ductwork is too small for the size of the furnace, or when too many supply vents are closed. Additionally, a dirty evaporator coil (the A-frame-shaped part of your central AC) can sit on top of the furnace and block airflow just like a dirty filter.



Is a high limit switch the same as a flame sensor?

No. A flame sensor is a thin metallic rod that sits in the flame to confirm ignition via a process called flame rectification. A high limit switch is a temperature-sensing safety device that monitors the heat of the air or the metal plenum. If your furnace starts and then shuts off after exactly 5 seconds, that is a flame sensor issue; if it runs for several minutes and then shuts down, it is likely a limit switch issue.



How much does it cost to have a professional replace a high limit switch?

An HVAC technician will typically charge a diagnostic fee (ranging from $75 to $150) plus the cost of the part and labor. Expect a total bill between $150 and $300. While the part is inexpensive, the technician is also checking the heat exchanger for cracks and verifying that the manifold gas pressure is correct, which are common reasons for overheating.

Professional HVAC Maintenance and Safety

Maintaining a healthy furnace requires consistent airflow management and annual inspections of the heat exchanger integrity. If resetting your high limit switch does not provide a permanent solution, consult a licensed HVAC professional to perform a static pressure test and combustion analysis to ensure your home remains safe and efficient.


Carrier Furnace Fan Limit Switch Location at Jeffrey Mangano blog

Carrier Furnace Fan Limit Switch Location at Jeffrey Mangano blog