How To Check Pressure Tank Pressure And Performance

How To Check Pressure Tank Pressure And Performance

VEVOR 34-Gallon Vertical Well Pressure Tank, Pre-Charged Pressurized ...

Checking a water well pressure tank requires isolating the system, draining the water column, and measuring the air charge with a standard tire gauge to verify it sits exactly two PSI below your pressure switch cut-in setting. Neglecting this routine diagnostic can cause premature pump cycling, diaphragm rupture, and catastrophic well system failure.


Pre-Operation & Equipment Checklist

Properly diagnosing a residential or commercial pressure tank requires a methodical approach and specific diagnostic tools to prevent system contamination or electrical hazards. Whether you are dealing with a standard captive-air bladder tank or a traditional galvanized air-over-water tank, having the right gear ensures an accurate reading without damaging the Schrader valve or internal bladder.



  • Essential Gear and Tools: Standard digital or analog tire pressure gauge, heavy-duty bicycle pump or portable air compressor, bucket, flathead screwdriver, and a clean rag or towel.
  • Mandatory Prerequisite Standards: You must locate your system's pressure switch cut-in and cut-off settings (typically 30/50 or 40/60 PSI) and verify that electrical power to the well pump is completely disconnected at the breaker panel.
  • Time and Cost Benchmarks: The diagnostic procedure takes approximately 15 to 30 minutes to complete. The required tools cost under twenty dollars, saving you hundreds in premature pump motor replacements or emergency plumber service calls.

Step-by-Step Pressure Tank Diagnostic Workflow



Step 1: Disconnect Power to the Well Pump

Locate your dedicated well pump circuit breaker in your home's main electrical panel and switch it to the OFF position.



  1. Walk to the pressure tank and verify that the pump is deactivated by checking that no automated cycles initiate.
  2. Leaving the power active while draining the system can cause the pressure switch to trigger while the tank is empty, leading to dry-running the pump or severe electrical arcs.

Warning: Never skip shutting off power at the main electrical panel. Operating plumbing fixtures while high-voltage well components are energized creates an immediate risk of severe electrical shock.



Step 2: Relieve System Water Pressure

Open the nearest hose spigot, utility sink faucet, or a drain valve located directly downstream from the pressure tank.



  1. Allow all accumulated water to drain completely out of the plumbing distribution network until the flow stops entirely and the pressure gauge on the manifold reads absolute zero.
  2. Keep this downstream faucet open for the duration of the testing procedure to allow trapped water inside the tank bladder to escape as you adjust the air charge.


Step 3: Locate and Inspect the Schrader Valve

Remove the protective plastic cap from the pressure tank's air valve, which resembles a standard automotive tire valve stem, usually located on top or underneath a side port.



  1. Inspect the valve core for signs of moisture, rust, or mineral scaling.
  2. If water continuously bubbles out of the valve stem when you press the internal pin, the internal bladder or diaphragm has ruptured, and the entire pressure tank must be replaced immediately.


Step 4: Measure the Pre-Charge Air Pressure

Press your tire pressure gauge firmly onto the Schrader valve stem to take an immediate air pressure reading.



  1. Compare this measured air pressure against your pressure switch settings.
  2. The golden rule of well maintenance is that the tank air pre-charge must measure exactly 2 PSI below the pump cut-in pressure (for example, if your switch is set to 30/50 PSI, your tank air pressure should read exactly 28 PSI).

Pro-Tip: Always take your pressure reading while the water system is completely drained of water and the drain valve remains fully open. Measuring pressure with water inside the tank will give you a false, artificially high reading.



Step 5: Adjust and Equalize the Air Charge

If your pressure gauge reading is lower than the target 2 PSI below cut-in threshold, attach your portable air compressor or bicycle pump to the Schrader valve.



  1. Pump air into the tank to raise the pressure, or release air using the valve pin if the pressure is too high.
  2. Once the target air pressure is stabilized, close your drainage faucet, turn the well pump circuit breaker back ON, and monitor the system as it refills to ensure normal cycling.

Amazon.com: 20 30 35 40 50 55 60 65 80gallon Water Pressure Tank for ...

Amazon.com: 20 30 35 40 50 55 60 65 80gallon Water Pressure Tank for ...

Pressure Tank Specifications and Switch Parameters



Switch Setting (Cut-In / Cut-Off) Target Air Pre-Charge (2 PSI Below Cut-In) Common Tank Model Match Typical Application
20 / 40 PSI 18 PSI Small Residential / Shallow Well Low-demand cabins, irrigation
30 / 50 PSI 28 PSI Standard Residential Well Average 3-4 bedroom household
40 / 60 PSI 38 PSI High-Demand Residential / Multi-Story Large homes, heavy water usage
50 / 70 PSI 48 PSI Commercial / Booster Systems Multi-family units, light commercial

Common Pressure Tank Failures and Field Fixes



  • Water Leaking from the Air Valve:

    • Root Cause: The internal butyl rubber bladder or diaphragm has torn or separated from the tank wall, allowing water to fill the upper air chamber.
    • Actionable Fix: Check the tank weight. If it feels completely heavy and waterlogged, the bladder has failed, and you must replace the pressure tank.
  • Rapid Pump Cycling (Short-Cycling):

    • Root Cause: The air pre-charge has dropped significantly due to air loss through a leaky valve core or micro-seep, leaving insufficient air cushion to absorb volume changes.
    • Actionable Fix: Drain the system completely, adjust the air pre-charge back to 2 PSI below the cut-in pressure, and replace the Schrader valve core if it fails a soap-bubble leak test.
  • Pump Fails to Shut Off:

    • Root Cause: A waterlogged tank or a stuck pressure switch diaphragm prevents the system from building enough pressure to trip the electrical contact points.
    • Actionable Fix: Clear sediment buildup out of the pressure switch nipple, verify accurate air pre-charge, and replace the switch if contacts are fused or burned.

Frequently Asked Questions



How often should I check my pressure tank air pressure?

You should test your pressure tank air charge at least once every six months to catch air loss or bladder degradation early. Regular seasonal checks prevent short-cycling that can burn out expensive submersible or jet pump motors.



What happens if the pressure tank air charge is too high?

If your air pre-charge is set higher than the pump cut-in pressure, your water system will experience dramatic pressure drops between pump cycles. You will notice surging water pressure at your faucets whenever you open a tap.



Can I add air to a pressure tank while there is water inside?

No, you must never add or check air pressure while the tank contains water under system pressure. Any air reading taken while water is inside will reflect the combined water and air pressure rather than the true bladder pre-charge.



How do I know if my pressure tank is waterlogged?

A waterlogged tank has lost all of its compressed air cushion, meaning the tank will feel uniformly heavy from top to bottom and your well pump will turn on every single time you flush a toilet or run a faucet for more than a few seconds.

Ensure optimal well pump longevity and consistent household water pressure by scheduling your routine bi-annual pressure tank inspection today.